Guide · Businesses · 3 min read · Updated 17 November 2026
Anti-Slip Factory Flooring: Rules, Testing and Options
Short answer
UK workplace floors must not be slippery so far as reasonably practicable under the Workplace (Health, Safety and Welfare) Regulations 1992. Slip resistance is commonly measured with the pendulum test, where HSE guidance treats a Pendulum Test Value of 36 or more as low slip potential. Resin floors are made anti-slip by adding aggregate, with more texture for oily or greasy conditions.
The legal requirement
The Workplace (Health, Safety and Welfare) Regulations 1992 require floors to be suitable for their purpose, free from holes, unevenness or slopes that create risk, and not slippery, so far as reasonably practicable. Employers must also keep floors free from obstructions and substances that could cause slips.
Slips and trips are among the most common causes of workplace injury, and the Health and Safety Executive publishes extensive guidance on preventing them. Flooring is only part of the answer. Cleaning, footwear, controlling spills and good housekeeping all play a role, but a floor that is slippery when contaminated is very hard to manage safely.
Risk assessments should identify where floors get wet or contaminated and what controls are in place.
How slip resistance is measured
The pendulum test is widely used in the UK to measure slip resistance. A swinging arm with a rubber slider sweeps across the floor, and the result is given as a Pendulum Test Value, or PTV. HSE guidance treats a PTV of 36 or more as low slip potential, values between 25 and 35 as moderate, and below 25 as high slip potential.
Surface roughness is a quicker indicator, measured with a roughness meter in microns. HSE guidance links roughness above about 20 microns with low slip potential for clean water conditions. Floors exposed to more viscous contaminants such as oils need rougher surfaces.
Testing should reflect real conditions. A floor tested dry may perform very differently when wet or oily, so pendulum tests are normally carried out with the floor wetted to show how it behaves when contaminated. Testing before and after installation, and periodically afterwards, gives a useful record of how the floor is performing over time.
| Pendulum Test Value (PTV) | Slip potential |
|---|---|
| 36 and above | Low |
| 25 to 35 | Moderate |
| Below 25 | High |
Anti-slip resin options
Resin floors are given slip resistance by adding aggregate. Fine aggregate such as quartz or aluminium oxide is broadcast into the wet resin and sealed. The size and amount of aggregate determine the texture. Light texture suits dry areas with occasional water. Heavier texture suits wet areas, and coarse textures suit oils, fats and greases.
Polyurethane screeds often include aggregate throughout the mix, with a textured finish suited to wet production areas. Choosing the right finish needs a clear understanding of what contaminates the floor, how often and how it is cleaned.
- Dry areas: light texture or smooth finish
- Occasional water: fine aggregate finish
- Regularly wet floors: medium texture
- Oils, fats and greases: coarse texture
- Ramps and slopes: extra texture
Balancing grip and cleaning
More texture usually means more grip, but it also makes cleaning harder. A very rough floor traps dirt and needs scrubbing machines and suitable brushes to keep clean. If cleaning cannot keep up, contamination builds up in the texture and slip resistance can fall.
The best result comes from matching texture to contamination and cleaning method. Ask the flooring contractor to consider your cleaning regime, and plan to update cleaning equipment if a new textured floor goes down. Smooth finishes may be acceptable in dry areas where cleanability matters most.
Common problem areas
Slips often happen at transitions: doorways where wet footwear enters dry areas, around sinks and washdown points, near machinery that leaks oil and at the bottom of ramps. These areas may need more texture than the surrounding floor, or matting and drainage to control contamination.
Worn floors are another risk. Anti-slip finishes wear down in high-traffic areas, especially under forklifts. A floor that tested well when new may become slippery after a few years. Periodic testing and recoating of worn areas maintains performance.
Footwear is the other half of the equation. Even a well-textured floor can be slippery with the wrong shoes, and suitable slip-resistant footwear can make a big difference on smoother floors. Flooring, cleaning and footwear should be considered together rather than in isolation, which is how HSE guidance approaches slip prevention.
Improving an existing floor
If an existing resin floor has become slippery, it may be possible to apply a new anti-slip topcoat after preparation, rather than replacing the whole floor. The surface is abraded, cleaned and recoated with aggregate. This is cheaper than a full new floor if the base system is sound.
Bare concrete floors can be treated with anti-slip coatings or sealed with an epoxy system with added aggregate. Typical costs run from £12–£25 per m² for thin coatings to £35–£60 per m² for self-smoothing systems with textured finishes. A survey confirms the best option and a fixed price.
Before committing to a full new floor, a test patch of the proposed anti-slip finish can be laid and checked. It shows how the texture looks, how it cleans with your equipment and how it feels underfoot, which helps staff and cleaning teams accept the change.
Questions people also ask
What PTV does a factory floor need?
HSE guidance treats a Pendulum Test Value of 36 or more as low slip potential under the conditions tested. Floors should be tested in the contamination they face, such as water or oil. Many specifiers aim for 36 or above in wet areas.
Can I make my existing factory floor less slippery?
Often yes. A worn resin floor can be prepared and recoated with an anti-slip topcoat containing aggregate. Bare concrete can be coated with a textured system. The right option depends on the floor's condition and contamination, which a survey identifies.
Does anti-slip flooring wear out?
The texture can wear down over time, especially under forklift traffic and in busy walkways. Slip resistance may fall as a result. Periodic checks and recoating worn areas maintain grip. Good cleaning also prevents contaminants building up in the texture.
Written and checked by the Factory Flooring team. Read our editorial policy.
More guides
How Much Does Factory Flooring Cost in the UK?
Factory flooring in the UK costs £12–£25 per m² for a light epoxy seal, £20–£40 per m² for high-build epoxy and £35–£60 per m² for 2–4 mm…
Epoxy vs Polyurethane Factory Flooring: Which Is Best?
Epoxy flooring suits dry warehouses, workshops and light to medium manufacturing. It is hard, durable and costs £20–£60 per m² depending on…
How Resin Factory Floors Are Installed: Step by Step
A resin factory floor is installed in stages. The contractor surveys and moisture-tests the slab, prepares it by shot blasting or diamond grinding,…
Food Factory Flooring Requirements in the UK
UK food factory floors must be kept in sound condition and be easy to clean and, where necessary, disinfect under food hygiene law, which usually…
Get a free factory flooring quote
Tell us what you need and we'll come back with a clear price.